By popularity (ascending)
By popularity (ascending)
#PROP_TITLE#
#PROP_VALUE#
Name
“CPR” mode only for the syringe with the rated capacity (volume) of 20 ml, single-drug injection (infusion) volume 5 ml
“CPR” mode only for the syringe with the rated capacity (volume) of 20 ml, single-drug injection volume 3 ml
AAA lithium battery, pc.
Battery life from accumulator, hour
Capacity of liquid collection cup, l, not less than
Capacity of ventilation bag, ml
Detected compression depth, cm
Detector dimensions, mm
Dimensions of the CPR indicator in the case, mm
Dimensions of the processing and indication unit, mm
Free air stream at maximal suction strokes, l/min
Inadvertent bolus protection function (“Anti-bolus”)
Infusion rate in the “Bolus” mode for the syringe with the rated capacity (volume) of 10 ml, ml/h; not adjusted
Infusion rate in the “Bolus” mode for the syringe with the rated capacity (volume) of 20 ml, ml/h; not adjusted
Infusion rate in the “Bolus” mode for the syringe with the rated capacity (volume) of 5 ml, ml/h; not adjusted
Internal diameter of suction tube, mm
Maximal vacuum kPa, 10 sec
Minute ventilation, l/min
Occlusion pressure, kp/cm2
Overall dimensions of the set, mm
Overall dimensions, mm
Pace, bpm
Power supply / accumulator
Power supply / car lighter socket
Power supply / main supply
Productivity in artificial vomit mass, l/min, not less than
Rated capacity (volume) of syringes used, ml
Water output, l/min, not less than
Weight of the set, kg
Weight, g
Air capacity, l/min
Water capacity, l/min
Artificial vomit capacity, l/min
Continuous operation time from internal power supply
Full charging time from internal power supply
Overall dimensions of the suction device, mm
Overall dimensions of the suction device in the case bag, mm
Volume of the collection container, ml
Weight of the suction device, kg
Weight, kg
Patient's chest height (range for the height of the initial position for the suction cup plunger), mm
Patient's chest width, mm
Operating mode setup time, s
Compression rate, 1/min
Compression depth (working amplitude of the patient's chest compressions), mm
Chest compression enhancement
Mode: 30 patient's chest compressions with the rate of (105±5) min-1, followed by a 3-second pause
Mode: 15 patient's chest compressions with the rate of (105±5) min-1, followed by a 3-second pause
Mode: continuous patient's chest compressions with the rate of (105±5) min-1
Sound alarms
Visual indication and alarms
Temporary disabling of sound alarms, min
Assembled device weight, kg
ARKA rucksack bag, mm
Assembled device dimensions, mm
Deviation of the positioning lighting line from the support plate symmetry axis along its whole width, mm
Autonomous device operating time with two completely charged batteries (at the ambient temperature of (25 ± 5) °C), min
Operating temperatures
Operation after operating storage and transportation at (20±4) °C beyond normal operating conditions at low temperatures
Operation after operating storage and transportation at (20±4) °C beyond normal operating conditions at high temperatures
Storage temperature
Transportation temperatures
Relative humidity during operation, storage, and transportation
Atmospheric pressure
Protection degree of the ARKA functional unit
Protection degree of the rechargeable battery
Protection degree of the charging device
Resistance to mechanical impacts during operation
Resistance to mechanical impacts during transportation
Average device service life (including storage, not accounting for the rechargeable battery service life) with the average operating intensity of 90 minutes per week, years
Expected service life (including shelf-life, if not stated otherwise) of the device according to GOST R IEC 60601-1
Recommended period for rechargeable battery replacement
Price
170-305
Maximum 450
Maximum 5
105±5
53±3
Automatic
30:2
15:2
Continuous (CONT)
Present
Present
5±0.1
7.9±20 %
620×350×230
573×552×240
Maximum 20
Minimum 92
-5 °C to +41 °C
–20 °C to –5 °C within minimum 1 hour
+41 °C to +50 °C within minimum 20 minutes
-20 °C to +60 °C
-20 °C to +60 °C
5-98 % (non-condensing)
62-107 kPa
IP43
IP44
IP40
Portable device (GOST R IEC 60601-1); Group 5 (GOST R 50444)
In the transport packaging. Group 5 (GOST R 50444)
Minimum 5
8 years
3 years or 200 uses (over 10 minutes long each)
Patient's chest height (range for the height of the initial position for the suction cup plunger), mm
170-305
Patient's chest width, mm
Maximum 450
Operating mode setup time, s
Maximum 5
Compression rate, 1/min
105±5
Compression depth (working amplitude of the patient's chest compressions), mm
53±3
Chest compression enhancement
Automatic
Mode: 30 patient's chest compressions with the rate of (105±5) min-1, followed by a 3-second pause
30:2
Mode: 15 patient's chest compressions with the rate of (105±5) min-1, followed by a 3-second pause
15:2
Mode: continuous patient's chest compressions with the rate of (105±5) min-1
Continuous (CONT)
Sound alarms
Present
Visual indication and alarms
Present
Temporary disabling of sound alarms, min
5±0.1
Assembled device weight, kg
7.9±20 %
ARKA rucksack bag, mm
620×350×230
Assembled device dimensions, mm
573×552×240
Deviation of the positioning lighting line from the support plate symmetry axis along its whole width, mm
Maximum 20
Autonomous device operating time with two completely charged batteries (at the ambient temperature of (25 ± 5) °C), min
Minimum 92
Operating temperatures
-5 °C to +41 °C
Operation after operating storage and transportation at (20±4) °C beyond normal operating conditions at low temperatures
–20 °C to –5 °C within minimum 1 hour
Operation after operating storage and transportation at (20±4) °C beyond normal operating conditions at high temperatures
+41 °C to +50 °C within minimum 20 minutes
Storage temperature
-20 °C to +60 °C
Transportation temperatures
-20 °C to +60 °C
Relative humidity during operation, storage, and transportation
5-98 % (non-condensing)
Atmospheric pressure
62-107 kPa
Protection degree of the ARKA functional unit
IP43
Protection degree of the rechargeable battery
IP44
Protection degree of the charging device
IP40
Resistance to mechanical impacts during operation
Portable device (GOST R IEC 60601-1); Group 5 (GOST R 50444)
Resistance to mechanical impacts during transportation
In the transport packaging. Group 5 (GOST R 50444)
Average device service life (including storage, not accounting for the rechargeable battery service life) with the average operating intensity of 90 minutes per week, years
Minimum 5
Expected service life (including shelf-life, if not stated otherwise) of the device according to GOST R IEC 60601-1
8 years
Recommended period for rechargeable battery replacement
3 years or 200 uses (over 10 minutes long each)
2
1-10
(94±5)х(60±5)х(8±2)
(135±10)х(100±5)х(33±5)
(90±5)х(60±5)х(21±2)
mask (125±5)х(102±5)х(77±5), case (151,3±5)х(114,6±5)х(47,4±5)
110
mask 42±3, case 70±5
0,15
AAA lithium battery, pc.
2
Detected compression depth, cm
1-10
Detector dimensions, mm
(94±5)х(60±5)х(8±2)
Dimensions of the CPR indicator in the case, mm
(135±10)х(100±5)х(33±5)
Dimensions of the processing and indication unit, mm
(90±5)х(60±5)х(21±2)
Overall dimensions, mm
mask (125±5)х(102±5)х(77±5), case (151,3±5)х(114,6±5)х(47,4±5)
Pace, bpm
110
Weight, g
mask 42±3, case 70±5
Weight, kg
0,15
infusion of 5 ml of the drug within not more than 16 sec every 4 min 5 sec ± 5 sec
infusion of 3 ml of the drug within not more than 8 sec every 4 min 5 sec ± 5 sec
10 (at least 10 h at the infusion rate of 600 ml/h using the syringe with the rated capacity (volume) of 20 ml)
yes
650-950
1000-1500
480-620
0,25 – 0,65
(167±5)х(92±5)х(32±5) (without adapter)
yes
yes
yes
Automatic detection of the syringe rated capacity (volume): 5, 10, 20
not more than 0,3
“CPR” mode only for the syringe with the rated capacity (volume) of 20 ml, single-drug injection (infusion) volume 5 ml
infusion of 5 ml of the drug within not more than 16 sec every 4 min 5 sec ± 5 sec
“CPR” mode only for the syringe with the rated capacity (volume) of 20 ml, single-drug injection volume 3 ml
infusion of 3 ml of the drug within not more than 8 sec every 4 min 5 sec ± 5 sec
Battery life from accumulator, hour
10 (at least 10 h at the infusion rate of 600 ml/h using the syringe with the rated capacity (volume) of 20 ml)
Inadvertent bolus protection function (“Anti-bolus”)
yes
Infusion rate in the “Bolus” mode for the syringe with the rated capacity (volume) of 10 ml, ml/h; not adjusted
650-950
Infusion rate in the “Bolus” mode for the syringe with the rated capacity (volume) of 20 ml, ml/h; not adjusted
1000-1500
Infusion rate in the “Bolus” mode for the syringe with the rated capacity (volume) of 5 ml, ml/h; not adjusted
480-620
Occlusion pressure, kp/cm2
0,25 – 0,65
Overall dimensions, mm
(167±5)х(92±5)х(32±5) (without adapter)
Power supply / accumulator
yes
Power supply / car lighter socket
yes
Power supply / main supply
yes
Rated capacity (volume) of syringes used, ml
Automatic detection of the syringe rated capacity (volume): 5, 10, 20
Weight, kg
not more than 0,3
17±2
5±0.5
500
not less than 45 minutes
not more than 3 hours
(172х172х211)±10
(300х190х215)±10
800
2.3
Air capacity, l/min
17±2
Water capacity, l/min
5±0.5
Artificial vomit capacity, l/min
500
Continuous operation time from internal power supply
not less than 45 minutes
Full charging time from internal power supply
not more than 3 hours
Overall dimensions of the suction device, mm
(172х172х211)±10
Overall dimensions of the suction device in the case bag, mm
(300х190х215)±10
Volume of the collection container, ml
800
Weight of the suction device, kg
2.3
mask (125±5)х(102±5)х(77±5), case (151,3±5)х(114,6±5)х(47,4±5)
mask 42±3, case 70±5
Overall dimensions, mm
mask (125±5)х(102±5)х(77±5), case (151,3±5)х(114,6±5)х(47,4±5)
Weight, g
mask 42±3, case 70±5
0,3
70
10
70
310х170х220
2
6
1,2
Capacity of liquid collection cup, l, not less than
0,3
Free air stream at maximal suction strokes, l/min
70
Internal diameter of suction tube, mm
10
Maximal vacuum kPa, 10 sec
70
Overall dimensions of the set, mm
310х170х220
Productivity in artificial vomit mass, l/min, not less than
2
Water output, l/min, not less than
6
Weight of the set, kg
1,2
Capacity of liquid collection cup, l, not less than
0,3
Free air stream at maximal suction strokes, l/min
70
Internal diameter of suction tube, mm
10
Maximal vacuum kPa, 10 sec
70
Overall dimensions of the set, mm
310х170х220
Productivity in artificial vomit mass, l/min, not less than
2
Water output, l/min, not less than
6
Weight of the set, kg
1,2
1650±200
31
(330х140х220)±20
0,93±20%
Capacity of ventilation bag, ml
1650±200
Minute ventilation, l/min
31
Overall dimensions of the set, mm
(330х140х220)±20
Weight, kg
0,93±20%
0,3
1650±200
70
10
70
31
(370х175х310)±20
2
6
3,06±20%
Capacity of liquid collection cup, l, not less than
0,3
Capacity of ventilation bag, ml
1650±200
Free air stream at maximal suction strokes, l/min
70
Internal diameter of suction tube, mm
10
Maximal vacuum kPa, 10 sec
70
Minute ventilation, l/min
31
Overall dimensions of the set, mm
(370х175х310)±20
Productivity in artificial vomit mass, l/min, not less than
2
Water output, l/min, not less than
6
Weight, kg
3,06±20%
350±100
5
(330х140х220)±20
0,84±20%
Capacity of ventilation bag, ml
350±100
Minute ventilation, l/min
5
Overall dimensions of the set, mm
(330х140х220)±20
Weight, kg
0,84±20%
0,3
350±100
70
10
70
5
(330х140х220)±20
2
6
1,76±20%
Capacity of liquid collection cup, l, not less than
0,3
Capacity of ventilation bag, ml
350±100
Free air stream at maximal suction strokes, l/min
70
Internal diameter of suction tube, mm
10
Maximal vacuum kPa, 10 sec
70
Minute ventilation, l/min
5
Overall dimensions of the set, mm
(330х140х220)±20
Productivity in artificial vomit mass, l/min, not less than
2
Water output, l/min, not less than
6
Weight, kg
1,76±20%
500±100
15
(330х140х220)±20
0,8±20%
Capacity of ventilation bag, ml
500±100
Minute ventilation, l/min
15
Overall dimensions of the set, mm
(330х140х220)±20
Weight, kg
0,8±20%
0,3
500±100
70
10
15
(330х140х220)±20
2
6
1,75±20%
Capacity of liquid collection cup, l, not less than
0,3
Capacity of ventilation bag, ml
500±100
Free air stream at maximal suction strokes, l/min
70
Internal diameter of suction tube, mm
10
Minute ventilation, l/min
15
Overall dimensions of the set, mm
(330х140х220)±20
Productivity in artificial vomit mass, l/min, not less than
2
Water output, l/min, not less than
6
Weight, kg
1,75±20%