Automatic compression machine for cardiopulmonary resuscitation “ARKA”
Patient's chest height (range for the height of the initial position for the suction cup plunger), mm
—
170-305
Patient's chest width, mm
—
Maximum 450
Operating mode setup time, s
—
Maximum 5
Compression rate, 1/min
—
105±5
Compression depth (working amplitude of the patient's chest compressions), mm
—
53±3
Chest compression enhancement
—
Automatic
Mode: 30 patient's chest compressions with the rate of (105±5) min-1, followed by a 3-second pause
—
30:2
Mode: 15 patient's chest compressions with the rate of (105±5) min-1, followed by a 3-second pause
—
15:2
Mode: continuous patient's chest compressions with the rate of (105±5) min-1
—
Continuous (CONT)
Sound alarms
—
Present
Visual indication and alarms
—
Present
Temporary disabling of sound alarms, min
—
5±0.1
Assembled device weight, kg
—
7.9±20 %
ARKA rucksack bag, mm
—
620×350×230
Assembled device dimensions, mm
—
573×552×240
Deviation of the positioning lighting line from the support plate symmetry axis along its whole width, mm
—
Maximum 20
Autonomous device operating time with two completely charged batteries (at the ambient temperature of (25 ± 5) °C), min
—
Minimum 92
Operating temperatures
—
-5 °C to +41 °C
Operation after operating storage and transportation at (20±4) °C beyond normal operating conditions at low temperatures
—
–20 °C to –5 °C within minimum 1 hour
Operation after operating storage and transportation at (20±4) °C beyond normal operating conditions at high temperatures
—
+41 °C to +50 °C within minimum 20 minutes
Storage temperature
—
-20 °C to +60 °C
Transportation temperatures
—
-20 °C to +60 °C
Relative humidity during operation, storage, and transportation
—
5-98 % (non-condensing)
Atmospheric pressure
—
62-107 kPa
Protection degree of the ARKA functional unit
—
IP43
Protection degree of the rechargeable battery
—
IP44
Protection degree of the charging device
—
IP40
Resistance to mechanical impacts during operation
—
Portable device (GOST R IEC 60601-1); Group 5 (GOST R 50444)
Resistance to mechanical impacts during transportation
—
In the transport packaging. Group 5 (GOST R 50444)
Average device service life (including storage, not accounting for the rechargeable battery service life) with the average operating intensity of 90 minutes per week, years
—
Minimum 5
Expected service life (including shelf-life, if not stated otherwise) of the device according to GOST R IEC 60601-1
—
8 years
Recommended period for rechargeable battery replacement
—
3 years or 200 uses (over 10 minutes long each)
Training simulator: CPR efficiency indicator "TEMP"
AAA lithium battery, pc.
—
2
Detected compression depth, cm
—
1-10
Detector dimensions, mm
—
(94±5)х(60±5)х(8±2)
Dimensions of the CPR indicator in the case, mm
—
(135±10)х(100±5)х(33±5)
Dimensions of the processing and indication unit, mm
—
(90±5)х(60±5)х(21±2)
Overall dimensions, mm
—
mask (125±5)х(102±5)х(77±5), case (151,3±5)х(114,6±5)х(47,4±5)
Pace, bpm
—
110
Weight, g
—
mask 42±3, case 70±5
Weight, kg
—
0,15
Syringe pump
“CPR” mode only for the syringe with the rated capacity (volume) of 20 ml, single-drug injection (infusion) volume 5 ml
—
infusion of 5 ml of the drug within not more than 16 sec every 4 min 5 sec ± 5 sec
“CPR” mode only for the syringe with the rated capacity (volume) of 20 ml, single-drug injection volume 3 ml
—
infusion of 3 ml of the drug within not more than 8 sec every 4 min 5 sec ± 5 sec
Battery life from accumulator, hour
—
10 (at least 10 h at the infusion rate of 600 ml/h using the syringe with the rated capacity (volume) of 20 ml)
Inadvertent bolus protection function (“Anti-bolus”)
—
yes
Infusion rate in the “Bolus” mode for the syringe with the rated capacity (volume) of 10 ml, ml/h; not adjusted
—
650-950
Infusion rate in the “Bolus” mode for the syringe with the rated capacity (volume) of 20 ml, ml/h; not adjusted
—
1000-1500
Infusion rate in the “Bolus” mode for the syringe with the rated capacity (volume) of 5 ml, ml/h; not adjusted
—
480-620
Occlusion pressure, kp/cm2
—
0,25 – 0,65
Overall dimensions, mm
—
(167±5)х(92±5)х(32±5) (without adapter)
Power supply / accumulator
—
yes
Power supply / car lighter socket
—
yes
Power supply / main supply
—
yes
Rated capacity (volume) of syringes used, ml
—
Automatic detection of the syringe rated capacity (volume): 5, 10, 20
Weight, kg
—
not more than 0,3
Aspirators
Air capacity, l/min
—
17±2
Water capacity, l/min
—
5±0.5
Artificial vomit capacity, l/min
—
500
Continuous operation time from internal power supply
—
not less than 45 minutes
Full charging time from internal power supply
—
not more than 3 hours
Overall dimensions of the suction device, mm
—
(172х172х211)±10
Overall dimensions of the suction device in the case bag, mm
—
(300х190х215)±10
Volume of the collection container, ml
—
800
Weight of the suction device, kg
—
2.3
Manual resuscitators
Overall dimensions, mm
—
mask (125±5)х(102±5)х(77±5), case (151,3±5)х(114,6±5)х(47,4±5)
Weight, g
—
mask 42±3, case 70±5
Aspirators
Capacity of liquid collection cup, l, not less than
—
0,3
Free air stream at maximal suction strokes, l/min
—
70
Internal diameter of suction tube, mm
—
10
Maximal vacuum kPa, 10 sec
—
70
Overall dimensions of the set, mm
—
310х170х220
Productivity in artificial vomit mass, l/min, not less than
—
2
Water output, l/min, not less than
—
6
Weight of the set, kg
—
1,2
Aspirators
Capacity of liquid collection cup, l, not less than
—
0,3
Free air stream at maximal suction strokes, l/min
—
70
Internal diameter of suction tube, mm
—
10
Maximal vacuum kPa, 10 sec
—
70
Overall dimensions of the set, mm
—
310х170х220
Productivity in artificial vomit mass, l/min, not less than
—
2
Water output, l/min, not less than
—
6
Weight of the set, kg
—
1,2
Manual resuscitators
Capacity of ventilation bag, ml
—
1650±200
Minute ventilation, l/min
—
31
Overall dimensions of the set, mm
—
(330х140х220)±20
Weight, kg
—
0,93±20%
Manual resuscitators
Capacity of liquid collection cup, l, not less than
—
0,3
Capacity of ventilation bag, ml
—
1650±200
Free air stream at maximal suction strokes, l/min
—
70
Internal diameter of suction tube, mm
—
10
Maximal vacuum kPa, 10 sec
—
70
Minute ventilation, l/min
—
31
Overall dimensions of the set, mm
—
(370х175х310)±20
Productivity in artificial vomit mass, l/min, not less than
—
2
Water output, l/min, not less than
—
6
Weight, kg
—
3,06±20%
Manual resuscitators
Capacity of ventilation bag, ml
—
350±100
Minute ventilation, l/min
—
5
Overall dimensions of the set, mm
—
(330х140х220)±20
Weight, kg
—
0,84±20%
Manual resuscitators
Capacity of liquid collection cup, l, not less than
—
0,3
Capacity of ventilation bag, ml
—
350±100
Free air stream at maximal suction strokes, l/min
—
70
Internal diameter of suction tube, mm
—
10
Maximal vacuum kPa, 10 sec
—
70
Minute ventilation, l/min
—
5
Overall dimensions of the set, mm
—
(330х140х220)±20
Productivity in artificial vomit mass, l/min, not less than
—
2
Water output, l/min, not less than
—
6
Weight, kg
—
1,76±20%
Manual resuscitators
Capacity of ventilation bag, ml
—
500±100
Minute ventilation, l/min
—
15
Overall dimensions of the set, mm
—
(330х140х220)±20
Weight, kg
—
0,8±20%
Manual resuscitators
Capacity of liquid collection cup, l, not less than
—
0,3
Capacity of ventilation bag, ml
—
500±100
Free air stream at maximal suction strokes, l/min
—
70
Internal diameter of suction tube, mm
—
10
Minute ventilation, l/min
—
15
Overall dimensions of the set, mm
—
(330х140х220)±20
Productivity in artificial vomit mass, l/min, not less than
—
2
Water output, l/min, not less than
—
6
Weight, kg
—
1,75±20%